pH / CONDUCTIVITY / SALINITY METER CPC-661
The most important features
- pH / conductivity meter for laboratory use.
- Measures pH, redox potential (ORP), conductivity, salinity, resistivity, TDS and temperature.
- Simultaneous observation of all the chosen functions results on the colour touch sreen.
- Wide measuring range enables measurements of all types of liquids both ultra pure and salines.
- Calibration in 1 to 3 points.
- In the pH function automatic correction of the pH standard solution value changes, along with the temperature changes for NIST standards.
- In the conductivity measurement function automatic selection of the temperature coefficient for natural and ultra pure water.
- Memory of 500 results.
- USB output.
- Small size and weight.
- Meets the GLP requirements.
In the pH and mV measurement function:
- Depending on the kind of applied electrode it may be used for clean water, sewage, soil, pastes, meat, cheese and other measurements.
- Calibration of the pH electrode in 1 ÷ 3 points with possibility of choosing the buffers value in a given range.
- Range of the entered calibration points: 1 point 0.000 ÷ 6.000 pH, 2 point 6.800 ÷ 7.100 pH, 3 point 8.000 ÷ 14.000 pH.
- Automatic detection of buffer solutions and standard solutions entered in the meters memory.
- Automatic correction of the pH standard solution value along with the temperature changes for NIST standards, what eliminates the necessity of the standard solution temperature adjustment.
- The NIST standard solutions entered in the meters memory are phtalate, phosphate and borax or bicarbonate (chosen when the meter is ordered). The solutions in 20°C have following values: 4.001 pH, 6.881 pH, 9.225 pH or 10.064 pH.
- Possibility of storing characteristics of 3 pH electrodes enables their quick replacement – very useful when using different types of electrodes specific for different types of samples.
- Automatic control of the electrode’s condition.
- Possibility of viewing the electrode's parameters (buffer and slope).
- Precise redox potential measurement (accuracy 0.1mV).
- The pH and conductivity measurement circuits are isolated, so there is no interference during simultaneous measurements.
- Automatic or manual temperature compensation.
In the conductivity measurement function:
- Wide measuring range enables measurements in ultra pure water as well as in high conductivity solutions.
- 6 sub-ranges switched automatically.
- The first sub range 0 to 20 µS/cm enables measurements of pure water with resolution up to the 3rd decimal place.
- In case of measurements of natural water with conductivity from 60 µS/cm to 1 mS/cm the meter enables using non-linear temperature compensation. The parameters of this type of water are determined in the norm EN27888:1999 and concern surface water, deep water and well water. This function lowers the measurement error.
- The measurement accuracy of the ultra pure water with temperature compensation was increased by automatic adjustment of the temperature α coefficient depending on the temperature and kind of trace contaminations.
- The reference temperature may be chosen between 25°C and 20°C.
- Calibration by entering the constant K in range 0.010 ÷ 20.000 cm-1 or in standard solutions in 1 to 3 points.
- Wide range of α coefficient 0 ÷ 10 % / °C chosen depending on the measured solution.
- Possibility to store constants K of 3 cells which cover whole measuring range.
- Automatic calculation of conductivity into salinity in NaCl or KCl on the basis of the real characteristics instead of a constant coefficient, what greatly increases the accuracy.
- Possibility of defining the TDS with entering the TDS coefficient in range 0.2 ÷ 1.0.
- Resistivity measurement function.
- Memory of 3 conductivity cells constant K values enables fast replacing in case of measurements in different ranges.
Other features:
- Internal clock with date.
- Collecting up to 500 data sets in the internal data-logger with temperature, time and date, single collecting and taking series of measurements of all measured functions.
- Non-volatile memory of the stored results and calibration data.
- HOLD function to freeze the actual measurements results on the screen.
- Stabilised reading signalisation.
- Storing the calibration validity date and signalising it to the user.
- Possibility of choosing the language of the displayed information : English, German, French, Italian, Spanish, Portuguese.
- Possibility of connecting with a PC by a USB connector.
- Software for data transmission and collection delivered in set.
- Up to 10 last Calibration Reports transfer to a PC for printout.
- Powered with 5V/1000mA USB power adapter.
- The meter meets the GLP requirements.
- 24 months of warranty for the meter.
The standard set includes: ECF-1 conductivity sensor, CT2S-121 temperature sensor with Pt-1000S resistor, EPS-1 pH electrode for measurements in clean water. It should not be used in other types of liquid. Measurements in liquids with sediments should be made with use of IJ-44A pH electrode, which enables measurements in various samples of both pure and contaminated liquids and semi-solids. Its unusual construction (”intermediate junction”) protects the real junction (diaphragma) of the electrode against clogging, ensures stable measurements in these types of liquids or semi-liquid masses, in which other electrodes stop working quickly. When properly handled and maintained the electrode's lifetime is longer than the standard electrodes. TECHNICAL DATA
pH fucntion
Function | pH | Redox/mV | Temperature |
---|---|---|---|
Range | -6.000 ÷ 20.000 pH | ±2000.0 mV | -50.0 ÷ 200.0 °C |
Accuracy (±1digit) |
±0.005 pH* | ±0.2 mV* | ±0.1 °C** |
Temperature compensation | -5 ÷ 110 °C | - | - |
Input impedance | >1012Ω | >1012Ω | - |
Conductivity function
Function | Conductivity | Salinity | Resistivity | Temperature |
---|---|---|---|---|
Range | 0 ÷ 1000 mS/cm |
NaCl 0 ÷ 296 g/l KCl 0 ÷ 239 g/l |
0.500 Ωcm ÷ 200 MΩcm | -50.0 ÷ 200.0 °C |
Accuracy (± 1 digit) |
up to 19.999 mS/cm ±0.20 %*, above 20.00 mS/cm: ±0.35 %* |
±2.00 %* | ±2 % of the measured value* | ±0.1 °C** |
Temp. compensation | -5 ÷ 70 °C | -5 ÷ 70 °C | -5 ÷ 70 °C | - |
α coefficient | 0.00 ÷ 10.00 %/°C | 0.00 ÷ 10.00 %/°C | 0.00 ÷ 10.00 %/°C | - |
K constant | 0.010 ÷ 20.000 cm -1 | - | - | - |
Other data
Power | Power adapter 5V 1000mA | |||
---|---|---|---|---|
Dimensions (mm) | L = 175, W = 140, H = 52 | |||
Weight | 420 g |
* | The accuracy of the meter only. |
** | The accuracy of the meter only. The total error includes the meters and probe’s accuracy.
In the range 0 ÷ 100 °C the acceptable error of the probe with Pt-1000S resistor: ±0.27 °C. |