CONDUCTIVITY METER CC–660
The most important features
- Very high accuracy laboratory conductivity meter.
- Wide measuring range.
- Measures conductivity, salinity, TDS, resistivity and temperature.
- 5” colour graphic touch screen.
- Calibration in 1 to 5 points.
- In the conductivity measurement function automatic selection of the temperature coefficient for natural and ultra pure water.
- Memory of 2000 data sets.
- USB output.
- Meets the GLP requirements.
Detailed description
The CC-660 conductivity meter belongs to the newest generation of measuring equipment. It is distinguished by high measurement’s accuracy, a large 5” colour graphic touch screen and additional features which make working easier.Characteristic features:
- Designed for measurements of conductivity, salinity, resistivity, TDS and temperature.
- Enables simultaneous measurement and displaying of results of conductivity or salinity or resistivity or TDS and temperature.
- A wide conductivity measurement range allows for the measurement of both ultra-pure waters and high salinity liquids.
- 6 measurement subranges are automatically switched.
- The first subrange, 0 to 20 µS/cm, enables measurements of re-distilled water with resolution down to three decimal places.
- The meter allows for automatic temperature coefficient substitution when measuring surface, deep, and well waters with conductivity ranging from 60 µS/cm to 1 mS/cm, what significantly simplifies the work.
- Increased accuracy of ultra-pure water measurements with temperature compensation is achieved by automatic adjusting of the α coefficient depending on the temperature and type of trace contaminants.
- Memory of parameters and the last calibration date of three conductivity cells.
- Possibility of entering the reference temperature within the range of 0 - 40°C.
- Three calibration types:
- in standards at the reference temperature;
- in standards at the current reference temperature - for selected types of standards, what does not require heating or cooling;
- by entering the K constant within the range of 0.010 - 20.000 cm-1.
Other features:
- Temperature measurement using a CT2S-121 sensor with a selected Pt-1000S resistor – with higher accuracy.
- Clock function with date.
- Collecting up to 2000 data sets in the internal data-logger with temperature, time and date, single collecting and also taking series of measurements with given time interval possible – all measured functions are stored. In case of collect series exceeding the memory capacity, the included computer software may be used.
- "HOLD" function allows you to freeze the actual results displayed on the screen.
- Signalisation of a stabilised measurement result.
- Non-volatile memory of the stored results and calibration data.
- Built-in USB interface allows you to transfer results stored in the device's memory or currently measured to a PC.
- Ability to transfer a report from the last ten calibrations to a computer.
- Exceeding the calibration due date notification.
- Selectable languages: Polish, English, German, French, Italian, Spanish, and Portuguese.
- The device meets the GLP requirements.
- 24-month warranty.
- IP64 protection class.
The device can be equipped with conductivity sensors suitable for the tested liquids,such as:
ECF-1 with a wide linearity range and metal electrodes;
EC-201t platinum for re-distilled and distilled water;
EC-210 for high concentrations above 400 mS/cm.
TECHNICAL DATA
| Function | Conductivity | Salinity | Resistivity | Temperature |
|---|---|---|---|---|
| Range | 0 ÷ 2000 mS/cm |
KCl 0 ÷ 239 g/l NaCl 0 ÷ 296 g/l |
0.500 Ωcm ÷ 200 MΩcm | -50.0 ÷ 200.0 °C |
| Accuracy (± 1 digit) |
up to 19.999 mS/cm ±0.10 %*, above 20.00 mS/cm: ±0.25 %* |
±2.00 %* | ±2 % of the measured value* | ±0.1 °C** |
| Temp. compensation | -5 ÷ 70 °C | -5 ÷ 70 °C | -5 ÷ 70 °C | - |
| α coefficient | 0.00 ÷ 10.00 %/°C | 0.00 ÷ 10.00 %/°C | 0.00 ÷ 10.00 %/°C | - |
| K constant | 0.010 ÷ 20.000 cm -1 | - | - | - |
| Power | Power adapter 5V 1000mA | |||
| Dimensions (mm) | L = 175, W = 140, H = 52 | |||
| Weight | 420 g | |||
| * | The accuracy of the meter only. |
| ** |
Accuracy of the meter, total accuracy is a sum of the meter and temperature sensor accuracy. In the range 0 ÷ 100 °C the maximal acceptable error of the used temperature sensor with PT-1000S resistor ±0,1 °C. |